Smart Data Models’ Candidates repository now includes a new candidate standard from the SunSpec Alliance: sunspec-models, with 7 candidate models for the data that solar inverters, batteries and meters expose: device identity, AC and DC measurements, ratings and settings, storage state and grid metering. The SunSpec model definitions are published under Apache-2.0. Like every candidate, each model comes with a JSON Schema, an NGSI-LD @context and all four example serializations (NGSI-v2 and NGSI-LD, key-values and normalized), each validated against its schema.
About the SunSpec Information Models
The SunSpec Information Models are the open, Modbus-based data models used by most PV inverter manufacturers, and SunSpec Modbus is one of the DER communication protocols allowed by IEEE 1547-2018. Each model has a number and a fixed list of named points (registers) with a type, units, a scale factor and, for states and alarms, named symbols. Model 1 identifies the device, the 100 series are the classic inverter models, the 200 series meters and the 700 series the IEEE 1547-2018 DER models. This candidate uses release v2026-04-20, which has 113 models.
The models
| Model | SunSpec model | What it reports | Points |
|---|---|---|---|
common |
1 | Manufacturer, model, options, version, serial number, Modbus address | 6 |
inverter_three_phase |
103 | Classic three-phase inverter: currents, voltages, power, energy, temperatures, operating state, events | 31 |
DERMeasureAC |
701 | IEEE 1547 DER AC measurement: totals and per phase, injected and absorbed energy, inverter and grid connection state, alarms | 60 |
DERCapacity |
702 | Nameplate ratings and current settings: power, apparent and reactive power, charge/discharge rates, voltage and current limits, supported control modes | 42 |
DERStorageCapacity |
713 | Storage energy rating and availability, state of charge, state of health | 5 |
DERMeasureDC |
714 | DC side, with one entry per DC port (PV string, battery…) | 7 + 11 per port |
ac_meter_abcn |
203 | Three-phase (wye) meter: currents, voltages, power, power factor, imported and exported energy | 62 |
One consistent example installation
SunSpec devices are read locally over Modbus and there is no open dataset of SunSpec readings, so the examples are synthetic, and say so. They describe one fictitious installation at the same instant: a 10 kW three-phase hybrid inverter producing 6.42 kW from two PV strings while charging its 10.24 kWh battery (66.5 % state of charge), seen both through the classic model 103 and the 700-series DER models, and a grid meter at the connection point.
Translation notes
- SunSpec names, verbatim. Entity types are the SunSpec model names (
DERMeasureAC,ac_meter_abcn…) and every attribute keeps its point name (W,PhVphA,TotWhInj…), so anyone who knows SunSpec recognises them at once. - Values already scaled. On the wire, SunSpec sends integers plus scale-factor registers. Here every value is given in its real unit (watts, volts, hertz…), so the
*_SFpoints are dropped; each description says which scale factor applied. - Readable states and alarms. Enumerations use SunSpec’s symbol names (
RUNNING,CONNECTED) and alarm bitfields become lists of the active alarm names. - Two small additions.
refCommonlinks each model to the device’scommonentity, anddateObservedrecords when a measurement was read. SunSpec itself has neither. - Licence checked at the source. The model definitions are Apache-2.0 in SunSpec’s GitHub repository. A few upstream inconsistencies (unit spellings, power factor as a fraction in one model and a percentage in others) are documented in the metadata.
Try it, and tell us what’s missing
These are Candidates: first, carefully sourced translations that are not yet official Smart Data Models subjects. The main open question is how they relate to the existing dataModel.Energy (InverterDevice, ThreePhaseAcMeasurement), dataModel.GreenEnergy (PhotovoltaicDevice, PhotovoltaicMeasurement) and dataModel.Battery models, which describe the same equipment with Smart Data Models attribute names; a mapping between the two is a natural next step. Other SunSpec models (DER controls and curves, batteries, weather stations, trackers) can follow.